Sales & Technical Support +86 18561533896
ZLVOLT ZLVOLT

Fast response

Get a Quote

Tell us your voltage, current and application — our sales & engineering team will reply within 24 hours.

Products

RIP/RIF Oil-Air Transformer Bushing

FBRG / FBRGL / EBRG / EBRGL Series | 12kV - 550kV | 630A - 5000A

RIP/RIF Oil-Air Transformer Bushing

Product Series: FBRG / FBRGL (composite housing), EBRG / EBRGL (porcelain housing); L = draw-lead type

Housing: Composite silicone or porcelain

Rated Voltage: 12kV - 550kV

Rated Current: 630A - 5000A

Dry-type capacitive condenser core, RIP (resin-impregnated paper) or RIF (resin-impregnated fiber) insulation

Oil-air interface for oil-immersed power transformers

Factory Lead Time Including Full Routine Testing
RIF (12kV–252kV) 4 Weeks
RIP (12kV–252kV) 6–8 Weeks
550kV & Heavy-Current Drawing Review

* Lead time begins upon mutual technical drawing sign-off and advance payment receipt. Applies to standard orders ≤ 30 units.

Main Technical Index

FBRG series draw-lead oil-air transformer bushing dimension drawing
Main Technical Index (per IEC 60137 / GB/T 4109 / Q/ZL-JS-501-2026)
Rated Equipment Voltage Um (kV)2440.572.5126252363550
Power Frequency Withstand, 1 min (kV)6195140 / 155230 / 255460 / 505520740 / 750
Lightning Impulse (BIL Full Wave, kV)125200325550105014251675
Chopped Wave Lightning Impulse (kV)138220358605115515681843
Switching Impulse Withstand (SIL, kV)————85010501300
Rated Current Ir (A)630 / 1250 / 2000 / 3150 / 4000 / 5000 (Draw-lead or Draw-rod)
Dielectric Dissipation Factor tanδ≤ 0.005 (≤ 0.5%, typical 0.30% - 0.40% at 20°C)
Partial Discharge at 1.2 Um/√3 (pC)≤ 5 pC (Routine Factory Test Standard; IEC limit ≤ 10 pC)
Minimum Nominal Creepage Distance≥ 31 mm/kV (Heavy / Very Heavy anti-pollution sheds)
Cantilever Bending Load (N)1,250 N - 5,000 N (per voltage class and mechanical specification)
Short-Time Withstand Current25 × rated current for 2 s (thermally guaranteed)
Rated Frequency (Hz)50 / 60 Hz

Higher insulation levels (e.g. 155/325 kV, 255/550 kV) and custom creepage distances are manufactured per transformer maker drawings.

Product Advantages & Engineering Highlights

Integrated Smart Online Monitoring Option: All 72.5kV to 550kV condenser bushings feature precision capacitive test taps compatible with real-time continuous Tan Delta & capacitance sensors.

Elimination of Bushing Fire & Explosion Hazards: According to CIGRE A2.37 and INMR field failure statistics, 48.7% of catastrophic transformer fires are initiated by aging oil-impregnated paper (OIP) bushing failures. ZLVOLT dry RIP and RIF condenser cores contain zero dielectric oil, eliminating bushing-initiated fire and explosion hazards, oil leakage, and routine oil maintenance over a 30+ year design life.

Alternative Ester Fluid (FR3 / MIDEL) Compatibility: Fully qualified for synthetic and natural ester dielectric liquids (Cargill Envirotemp FR3 and Shell MIDEL 7131) up to 500 kV. Furnished with high-temperature Viton™ (FKM) fluorocarbon elastomer seals per modern utility green-substation requirements.

Solid Dry RIP/RIF Condenser Core: 100% oil-free and gas-free construction with void-free dielectric layering.

CNC Closed-Loop Servo Winding: Tension uniformity controlled within ±2 N with robotic foil alignment (±0.1 mm) ensures void-free dielectric layering, maintaining partial discharge ≤ 5 pC at 1.2 Um/√3 and tan δ ≤ 0.35% at 20°C.

IEEE 693 High Seismic Compliance: Reinforced fiberglass composite core and heavy-duty flange casting qualified for 0.5g / 1.0g peak ground acceleration and severe cantilever bending moments.

Extreme Temperature Performance (-50°C to +55°C): Dual fluorosilicone O-rings and cryogenic-resistant resin matrix prevent seal embrittlement in Arctic climates and high-altitude mountain substations.

Hydrophobic HTV Silicone Housing: Direct vulcanization with chemical silane coupling bonding delivers persistent hydrophobicity transfer under severe coastal salt fog, desert sand, and industrial pollution (Class IV / Class E, ≥31 mm/kV).

Smart Condition Monitoring Ready: Standard precision capacitive test tap connects directly to Doble, OMICRON, and Qualitrol online diagnostic systems for continuous C1/C2 tan δ tracking and DFR frequency domain spectroscopy.

1-to-1 Retrofit Compatibility: Customized mounting flange PCD, oil-side CT pocket length, and draw-lead/draw-rod interfaces allow direct dimensional replacement of legacy OIP bushings from ABB, Siemens, Trench, or Micafil.

Suitable Service Conditions

Installation Angle: Any angle.

Environment: Indoor and outdoor; severe pollution, high humidity, severe cold and high-altitude (above 2000 m) versions available by agreement.

Ordering Information

When placing an order, please specify:

1. Electrical Parameters: Rated voltage, rated current, frequency, creepage distance class, oil-side length, draw-lead length (critical), CT mounting position length (critical).

2. Environmental Parameters: Ambient temperature range, pollution level, altitude.

3. Interfaces: Flange drawing of the transformer, terminal type, whether a test tap / voltage tap is required.

Note: Flange and terminal dimensions can be custom-designed to the transformer maker's drawings. Direct replacement engineering for existing installations is available.

Engineering & Selection Guides

Reference Projects

Projects Using Oil-Air Transformer Bushings

All reference projects →

Product Recommendations

Explore Other Bushing Models

Model selection support

Need help with RIP/RIF Oil-Air Transformer Bushing?

Send your voltage, current and application — Daniel Yuan will reply by email.

Daniel Yuan International Commercial Manager +86 18561533896 (WhatsApp) sales@zlvolt.com
Get a Quote 📋 Chat on WhatsApp 💬