Technical Documentation & Downloads

Bushing Technical Documents & Report Requests

20 official third-party test reports issued by CTQC under IEC 60137:2017 and GB/T 4109-2022. English versions of 8 flagship model reports, additional dossiers and project CADs are sent by email on request.

Accredited Testing Authority
Applicant / Manufacturer:
Testing Laboratory CTQC China National Transformer Quality Inspection and Testing Center (Shenyang)
Laboratory Accreditation CNAS L0681 Under ILAC-MRA International Mutual Recognition Arrangement
Power Testing Liaison CHPTL China High Power Testing Liaison. The Shenyang Transformer Institute laboratory is listed as a member in the reports.
Compliance Norms IEC 60137:2017 Ed. 7.0 • IEEE C57.19.00/.01 • GB/T 4109-2022

Third-Party Verification Portfolio

CTQC Test Reports (20 Dossiers)

Select a category below to filter our type test portfolio. Use the Request button on any row and leave your email; the English report, tender dossier, dimensional CAD prints and routine factory test certificates are sent by email after an engineering inquiry.

Voltage Model Series Category / Application Rated Current Report No. Language / Available Dossiers Verified Test Scope Action / Access
550kV EGRG-550/5000 GIS Bushing
GIS Bushing (Porcelain / Solid Dry Core)
5000A CTQC/ZJ-23.0957
Issued: 2024-01
Official English Available
2 Editions (EN + ZH)
5000A thermal run, 1-min PF 740kV, BIL 1675kV, SIL 1300kV, PD ≤ 5pC at 1.5 Um/√3, SF6 annual leakage ≤ 0.05%
Request by Email English PDF, sent by email
363kV FGRG-363/5000 GIS Bushing
GIS Bushing (Silicone Composite Housing)
5000A CTQC/ZJ-25.1191
Issued: 2025-06
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
Full 5000A continuous heat run, 1-min PF 520kV, BIL 1425kV, SIL 1050kV, cantilever bending 5000N, gas tightness verification Request Dossier →
252kV PEGRG-252/3150(4000) GIS Bushing
GIS Bushing (RIP Resin-Impregnated Paper Core)
3150A / 4000A CTQC/ZJ-26.0558
Issued: 2026-05
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
Dual current rating (3150A / 4000A), BIL 1050kV, 1-min PF 460kV, routine PD ≤ 5pC, solid RIP capacitive core Request Dossier →
252kV EGRG-252/3150 GIS Bushing
GIS Bushing (Porcelain Housing)
3150A CTQC/ZJ-26.1183
Issued: 2026-09
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
BIL 1050kV, 1-min PF 460kV, cantilever 5000N, helium mass spectrometer leak check ≤ 1×10⁻⁶ Pa·m³/s Request Dossier →
363kV PFBRGL-363/5000 Transformer RIP
Transformer Bushing (RIP Resin-Impregnated Paper)
5000A CTQC/ZJ-25.1533
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
5000A continuous current run, BIL 1425kV, SIL 1050kV, 1-min dry PF 520kV, Tanδ ≤ 0.0037, PD < 4pC
Request by Email English PDF, sent by email
252kV PFBRGL-252/5000 Transformer RIP
Transformer Bushing (RIP Resin-Impregnated Paper)
5000A CTQC/ZJ-25.1532-1
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
5000A continuous thermal run, BIL 1050kV, 1-min PF 460kV, Tanδ ≤ 0.0038, seismic acceleration AG5 (0.4g)
Request by Email English PDF, sent by email
126kV PFBRGL-126/4000 Transformer RIP
Transformer Bushing (RIP Resin-Impregnated Paper)
4000A CTQC/ZJ-25.1530
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
4000A heat run, BIL 550kV, 1-min PF 230kV, Tanδ ≤ 0.0032, cantilever load 4000N, zero oil/SF6 maintenance-free
Request by Email English PDF, sent by email
363kV FBRGL-363/1250-3 Transformer Composite
Transformer Bushing (RIF Composite Housing)
1250A CTQC/ZJ-15.085
Issued: 2016-01
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
BIL 1300kV, SIL 950kV, 1-min PF 510kV, heavy pollution Class IV HTV silicone rubber weather sheds Request Dossier →
252kV FBRGL-252/5000 Transformer Composite
Transformer Bushing (RIF Composite Housing)
5000A CTQC/ZJ-25.1531
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
5000A high current continuous test, BIL 1125kV, SIL 887kV, 1-min PF 460kV, hydrophobic silicone rubber shed, PD < 3pC
Request by Email English PDF, sent by email
126kV FBRGL-126/4000 Transformer Composite
Transformer Bushing (RIF Composite Housing)
4000A CTQC/ZJ-25.1529
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
4000A continuous test, BIL 550kV, 1-min PF 230kV, Tanδ ≤ 0.0039, explosion-proof composite silicone housing
Request by Email English PDF, sent by email
72.5kV FBRGL-72.5/4000 Transformer Composite
Transformer Bushing (RIF Composite Housing)
4000A CTQC/ZJ-25.1528
Issued: 2025-08
Official English Available
2 Editions (EN + ZH)
4000A heat run, BIL 325kV, 1-min PF 140kV, Tanδ ≤ 0.0036, routine dielectric certified
Request by Email English PDF, sent by email
550kV EBRGL-550/1250 Transformer Porcelain
Transformer Bushing (Porcelain Housing)
1250A CTQC/ZJ-22.0031
Issued: 2022-04
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
BIL 1675kV, SIL 1300kV, 1-min PF 740kV, cantilever 12,500N, certified for 500kV substation grid step-up Request Dossier →
363kV EBRGL-363/1600 Transformer Porcelain
Transformer Bushing (Porcelain Housing)
1600A CTQC/ZJ-25.0914
Issued: 2025-04
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
BIL 1425kV, SIL 1050kV, 1-min PF 520kV, Tanδ ≤ 0.0038, high mechanical cantilever strength Request Dossier →
126kV ECRG-126/3150 Wall Bushing
Wall Penetration Bushing (Solid Dry Core)
3150A CTQC/ZJ-22.0207
Issued: 2022-05
ZH Certified + EN Summary
1 Edition (ZH Certified + EN Summary)
3150A indoor-outdoor wall penetration, BIL 550kV, 1-min PF 230kV, zero oil/SF6 maintenance-free core Request Dossier →
40.5kV (P)EBRG-40.5/25000 High Current Bushing
Generator High-Current Bushing (Solid Dry Core)
25,000A CTQC/ZJ-26.0046
Issued: 2026-04
Official English Available
2 Editions (EN + ZH)
Extreme 25,000A continuous current rating, 100kA/2s short-time withstand, 1-min PF 95kV, BIL 196kV, specialized busbar interface
Request by Email English PDF, sent by email

Standard Routine Testing on Every Production Unit: In addition to these third-party type test reports, 100% of bushings manufactured at our Beijing facility undergo mandatory factory acceptance routine testing: power frequency dry withstand, partial discharge test (PD ≤ 5pC), dielectric dissipation factor (tanδ ≤ 0.4%), capacitance measurement ($C_1$), and tightness verification.

Tender Documentation & Submissions

Verified Technical Packages for EPCs & Utilities

When submitting tenders to national transmission system operators (TSOs) or electrical utility asset owners, standardized documentation is critical. Our export engineering office provides comprehensive pre-qualification dossiers under the corporate legal name .

Packages include unredacted type test reports, routine test certificates, seismic calculation sheets, CAD mounting interface prints, and certificate of origin (CO) verification.

  • Routine partial discharge test on every unit
  • Tanδ and capacitance measurement at multiple voltage steps
  • Power frequency withstand and lightning impulse type tests
  • Sealing and pressure tightness verification
  • Mechanical bending load verification
  • Third-party type test and inspection reports on request
Request Dossier on WhatsApp → Email Export Engineering →

Voltage & Product Coverage

24kV Class (Dry Core)40.5kV Class (up to 25,000A)72.5kV Class (Composite RIF)126kV Class (RIP / RIF)252kV Class (RIP / Composite / GIS)363kV Class (5000A RIP / GIS)550kV Class (Porcelain & GIS)GIS Bushing Series (72.5–550kV)Wall Bushing Series (24–550kV)High Current Generator Bushings

Operation & Maintenance

Installation, Operation & Maintenance Guides

Official enterprise standard manuals covering lifting, torque requirements, gas pressure monitoring, and pre-commissioning tests.

Q/ZL-JS-501-2026

Dry-Type Transformer Bushing O&M Guide

Standard technical specifications for 40.5kV–550kV RIP/RIF capacitor transformer bushings: horizontal/vertical lifting procedures, draw-lead/draw-rod tightening torques, oil-level observation, and pre-energization routine test criteria.

Applicable: 40.5kV–550kV Edition: 2026 Official English
Request English Manual PDF →
Q/ZL-JS-502-2026

Dry-Type GIS Bushing O&M Guide

Technical requirements for 72.5kV–550kV RIP/RIF GIS bushings: SF6 interface sealing protocol, rated pressure (0.45–0.60 MPa) monitoring, moisture limits (≤ 250 μL/L), and contact resistance verification (≤ 50 μΩ).

Applicable: 72.5kV–550kV GIS Edition: 2026 Official English
Request English Manual PDF →