Voltage Range
Product Center
High Voltage Bushings: RIP & RIF Dry-Type, 12kV–550kV
RIP/RIF dry-type capacitive bushings for transformers, GIS, wall penetration and high-current applications. Compliant with IEC 60137:2017 & GB/T 4109-2022.
Standard Max (40,000A Custom)
Routine Partial Discharge
Min. Nominal Creepage
Dry-type bushing models for transformer, GIS and wall applications
Composite or porcelain housing, draw-rod and draw-lead conductor designs. All models are oil-free, gas-free, moisture-proof and maintenance-free — the ideal replacement for traditional oil-paper bushings.
RIP/RIF Oil-Air Transformer Bushing
12kV - 550kVDry-type capacitive transformer bushings with FRP laminate cores, composite or porcelain housing, draw-rod and draw-lead designs.
RIP/RIF GIS Bushing
72.5kV - 550kVSF6-to-air bushings that connect gas-insulated switchgear to overhead lines and air-insulated equipment, up to 5000A.
RIP/RIF Oil-SF6 Bushing
40.5kV - 550kVTransition bushings engineered for transformer-to-SF6 equipment interfaces with 5000N bending strength.
RIP/RIF Oil-Oil Bushing
72.5kV - 252kVOil-to-oil capacitive bushings for transformer internal connections and retrofits of installed units.
RIP/RIF Wall Bushing
24kV - 550kVOutdoor-indoor wall penetration bushings, export-proven at 252kV including Russian oil & gas projects.
RIP/RIF High Current Bushing
24kV - 40.5kV / up to 31,500A (40,000A custom)High-current dry-type bushings for generator transformers, furnace transformers and heavy industrial loads.
Technical specifications
Voltage class, CT mounting and typical application reference
Use the table below as an early selection reference. Final dimensions, creepage distance and conductor configuration should be confirmed against the transformer or GIS drawing.
| Rated Voltage (kV) | CT Mounting (mm) | Typical Application |
|---|---|---|
| 24 / 36 | 0 / 150 / 250 / 400 | Distribution transformers and compact substations |
| 40.5 | 0 / 150 / 250 / 400 | Industrial transformers and wind/PV collector substations |
| 72.5 | 0 / 250 / 400 / 550 | Substation transformers and retrofit programs |
| 126 - 170 | 250 / 400 / 550 | High-voltage grid transformers, wind and solar booster stations |
| 252 | 200 / 400 / 500 / 700 | EHV substations, storage conversion transformers |
| 363 - 550 | 200 / 400 / 500 / 700 | EHV substations, GIS interfaces, generator transformers |
Application scenarios
Where Zhonglian Kechuang bushings are typically used
Wind & Solar Power Plants
Bushings for main and station transformers across 800+ wind and PV projects, from 110kV collector substations to 330kV booster stations.
Energy Storage Stations
Dry-type bushings for storage conversion transformers, including 100MW+ grid-scale stations.
Substations & Grid
State Grid and Southern Grid transformer and GIS bushings, 72.5kV to 550kV, in service since 2013.
Industry & Rail Traction
Steel, coal, chemical and traction power applications, including high-current solutions up to 31,500A (custom to 40,000A).
Engineering Resources
Bushing Selection & Technical Knowledge Guides
In-depth technical guides for electrical engineers, transformer OEMs, and substation designers:
Transformer Bushing Selection Guide
Connection media, electrical ratings coordination (BIL/SIL), conductor ampacity, and turret mounting interfaces.
RIP vs. RIF Bushings
Dielectric core comparison: crepe paper vs. non-hygroscopic synthetic fiber, thermal endurance, and seismic withstand.
Type Tests vs. Routine Tests Guide
Factory Acceptance Testing (FAT), routine partial discharge screening (≤5 pC), and type-test witness verification.
GIS vs. Oil-SF6 Bushings
Gas-to-air penetrations vs. enclosed oil-to-gas transition bushings: boundary media and leak prevention.
Transformer Bushing RFQ Specification
Essential electrical, mechanical, CT turret, and seismic parameters required for fast quotation turnaround.
Model selection support
Need help selecting a bushing model?
Send your voltage, current and application — Daniel Yuan will reply with a recommendation.