Sales & Technical Support +86 18561533896
ZLVOLT ZLVOLT

Fast response

Get a Quote

Tell us your voltage, current and application — our sales & engineering team will reply within 24 hours.

Products

RIP/RIF Wall Bushing

FCRG / ECRGL Series | 24kV - 550kV | 630A - 5000A

RIP/RIF Wall Bushing

Product Series: FCRG (composite housing) / ECRGL (porcelain housing)

Rated Voltage: 24kV - 550kV

Rated Current: 630A - 5000A

Outdoor-indoor wall penetration bushing

Export-proven at 252kV/2000A (Tatneft, Russia)

Factory Lead Time Including Full Routine Testing
RIF (12kV–252kV) 4 Weeks
RIP (12kV–252kV) 6–8 Weeks
550kV & Heavy-Current Drawing Review

* Lead time begins upon mutual technical drawing sign-off and advance payment receipt. Applies to standard orders ≤ 30 units.

Main Technical Index

Main Technical Index (per IEC 60137 / GB/T 4109 / Factory Standards)
Rated Equipment Voltage Um (kV)2440.572.5126252363550
Power Frequency Withstand, 1 min (kV)6195140230460520740
Lightning Impulse Withstand (BIL, kV)125200325550105014251675
Switching Impulse Withstand (SIL, kV)————85010501300
Rated Current (A)630 / 1250 / 2000 / 3150 / 4000 / 5000
Dielectric Dissipation Factor tanδ≤ 0.005 (≤ 0.5%, typical 0.30% - 0.40% at 20°C)
Partial Discharge at 1.2 Um/√3 (pC)≤ 5 pC (Routine Factory Test Standard)
Cantilever Bending Load (N)≥ 1,250 N - 5,000 N (per voltage class and mounting span)
Housing StructureOutdoor: Hydrophobic HTV Composite Silicone or Porcelain; Indoor: Smooth or Shedded FRP/Porcelain
Mounting ConfigurationHorizontal, vertical, or angled through-wall mounting plate with custom bolt PCD

Note: Wall sleeve length, indoor/outdoor span, flange mounting diameter and terminal stud geometry are manufactured according to substation architectural wall drawings.

Product Advantages & Engineering Highlights

Heavy-Duty Mechanical Cantilever & Seismic Rigidity: Engineered with a reinforced central mounting collar and high-modulus FRP tube to withstand continuous horizontal bending moments from self-weight, terminal cable tension, and IEEE 693 seismic vibrations.

Eddy-Current Induction Loss Mitigation: Non-magnetic stainless steel or high-strength aluminum mounting flange inserts prevent closed circular eddy-current loops and localized induction heating in building concrete rebar.

Solid Dry Fire-Retardant & Hermetic Barrier: Solid RIP/RIF dry core with Class F thermal endurance acts as a natural flame-retardant and hermetic barrier between outdoor switchyards and indoor control halls; the oil-free, gas-free construction removes bushing oil-leakage risk by design.

Asymmetric Indoor/Outdoor Environment Adaptation: Custom shed profiles accommodate sharp temperature and pollution differentials between heated/air-conditioned indoor switchrooms and extreme outdoor ambient (-50°C to +55°C).

Proven EHV Performance: Up to 252kV/2000A in continuous service — including 18 units delivered to Tatneft, Russia, operating reliably since 2016.

Online Measurement & Diagnostic Tap: Factory-installed capacitive test tap facilitates continuous insulation monitoring and power-frequency capacitance / tan δ verification.

Typical Applications

  • Power station and substation wall penetrations, 24kV-252kV
  • Industrial plants: steel, coal, chemical, oil & gas
  • Railway traction power supply buildings

Ordering Information

Please specify rated voltage and current, wall thickness and opening drawing, indoor/outdoor side lengths, creepage class and whether a voltage tap is required.

Engineering & Selection Guides

Reference Projects

Projects Using Wall Bushings

All reference projects →

Product Recommendations

Explore Other Bushing Models

Model selection support

Need help with RIP/RIF Wall Bushing?

Send your voltage, current and application — Daniel Yuan will reply by email.

Daniel Yuan International Commercial Manager +86 18561533896 (WhatsApp) sales@zlvolt.com
Get a Quote 📋 Chat on WhatsApp 💬