RIP/RIF Oil-SF6 Bushing

YQRGL Series | 40.5kV - 550kV | 630A - 4000A

RIP/RIF Oil-SF6 Bushing

Product Series: YQRGL

Rated Voltage: 40.5kV - 550kV

Rated Current: 630A - 4000A

Bending Strength: ≥ 3150N - 5000N

Dry-type capacitive core for transformer-to-SF6 switchgear enclosed transition

Oil-side and SF6-side flange interfaces tailored per customer agreement

Factory Lead Time Including Full Routine Testing
RIF (12kV–252kV) 4 Weeks
RIP (12kV–252kV) 6–8 Weeks
550kV & Heavy-Current Drawing Review

* Lead time begins upon mutual technical drawing sign-off and advance payment receipt. Applies to standard orders ≤ 30 units.

Main Technical Index

Main Technical Index (per IEC 60137 / GB/T 4109 / Q/ZL-JS-502-2026)
Rated Equipment Voltage Um (kV)40.572.5126252363550
Power Frequency Withstand, 1 min (kV)95140230460520740
Lightning Impulse Withstand (BIL, kV)200325550105014251675
Switching Impulse Withstand (SIL, kV)———85010501300
Rated Current Ir (A)630 / 1250 / 2000 / 2500 / 3150 / 4000
Dielectric Dissipation Factor tanδ≤ 0.004 (≤ 0.40%, typical 0.30% at 20°C)
Partial Discharge at 1.2 Um/√3 (pC)≤ 5 pC (Routine Factory Test Standard)
SF6 Operating / Proof PressureRated 0.45 - 0.60 MPa / Proof Test 0.80 MPa
Cantilever Bending Load (N)≥ 3150 / 4000 / 5000 N per mechanical class

Product Advantages & Engineering Highlights

Direct Enclosed Transition: Connects transformer oil directly to SF6 switchgear busducts in a single hermetically sealed, dry-type capacitive core — eliminating open-air bushings and substation clearance constraints.

Hermetic Dual-Stage Barrier with Sniffer Port: Dual-groove fluorosilicone seals with an intermediate test chamber prevent SF6 cross-contamination into transformer oil and vice versa, tested to a helium leak rate < 1 × 10−6 mbar·l/s.

Eco-Gas (C4F7N / Clean Air) Ready: Solid resin core and field grading screens are fully compatible with both conventional SF6 gas and emerging eco-efficient gas mixtures (C4F7N / synthetic dry air).

Full EHV Coverage (40.5kV to 550kV): Accommodates rated currents up to 4000A with proof test pressure of 0.80 MPa on the gas side.

Solid RIP/RIF Explosion-Proof Core: 100% dry, cured insulation contains zero pressurized oil or gas inside the core body, eliminating fire hazards and oil-level maintenance.

1-to-1 Retrofit Compatibility: Tailor-machined mounting collars and CT pocket extensions allow drop-in replacement of aging OIP oil-SF6 bushings without modifying existing GIS gas compartments.

Typical Applications

  • Transformer-to-GIS/GIL direct enclosed connections from 40.5kV to 550kV
  • Compact indoor and underground substations requiring complete elimination of open air bushings
  • Thermal and hydro power station generator step-up (GSU) transformer connections to GIS busducts
  • Retrofit replacement of aging oil-paper insulated (OIP) oil-SF6 transition bushings

Ordering Information

Please specify rated voltage and current, insulation levels, both-side flange drawings, SF6-side and oil-side lengths, CT requirements and ambient conditions.

Engineering Guide: For detailed flange geometry, CT pocket verification, and media boundary comparisons between YQRGL oil-to-SF6 bushings and FGRGL/EGRGL gas-to-air GIS bushings, consult our GIS vs Oil-SF6 Bushings Interface Guide.

Engineering & Selection Guides

Product Recommendations

Explore Other Bushing Models

Model selection support

Need help with RIP/RIF Oil-SF6 Bushing?

Send your voltage, current and application — Daniel Yuan will reply by email.

Daniel Yuan International Commercial Manager +86 18561533896 (WhatsApp) sales@zlvolt.com
Get a Quote 📋 Chat on WhatsApp 💬